TDR200 Time-Domain Reflektometer
Zentraleinheit des TDR-Systems
wetter  wasser  energie  gas flux and turbulence  bauwerke  boden

Überblick

Das TDR200 Time-Domain Reflektometer ist das Herzstück des TDR-Systems von Campbell Scientific. über TDR kann man sehr genau den Bodenwassergehalt, die elektrische Leitfähigkeit des Bodens, Verschiebungen an Felsen oder andere kundenspezifische Parameter bestimmen. Ein Datenlogger von Campbell Scientific kann mehrere TDR200s steuern. 

Lesen Sie mehr

Funktionen und Vorteile

  • Low power (half the power of the TDR100)
  • Robust
  • High sensitivity
  • High resolution
  • Low noise
  • Advanced waveform filtering
  • Advanced waveform analysis algorithm
  • Backward compatible with TDR100 systems (CRBasic data loggers only)
  • 60 Hz frequency rejection

Bilder

Front view
Front view
Front view
Glam view
Front view
Front tilt view
Front tilt view
Back view
Right view
Top view
Bottom view

Zugehörige Produkte

Technische Beschreibung

The TDR200 generates a short rise time electromagnetic pulse that is applied to a coaxial system that includes a TDR probe for soil water measurements. Then the reflectometer samples and digitizes the resulting reflection waveform for analysis or storage.

The elapsed travel time and pulse reflection amplitude contain information used by the on-board processor to quickly and accurately determine soil volumetric water content, soil bulk electrical conductivity, rock mass deformation, or a user-specific time-domain measurement.

The data logger collects a 250-point waveform and analyzes it in approximately two seconds. Each waveform can have up to 10,112 data points for monitoring long cable lengths used in rock mass deformation or slope stability. Advanced noise filtering and averaging make accurate measurements possible in noisy environments.

A Complete System

A complete TDR200-based system includes the TDR200, SDM8X50 multiplexers, data logger, power supply, enclosures, and probes. PC-TDR version 3 software supports TDR200 and sensor setup, troubleshooting, and program generation. This software is available, at no charge, from our website.

The SDM8X50 Multiplexer brochure, TDR Probes component category brochure, and Time-Domain Reflectometry System brochure provide additional information about the TDR system components. 

Spezifikationen

Pulse Generator Output 250 mV into 50 Ω
Output Impedance 50 Ω ±1%
Time Response of Combined Pulse Generator & Sampling Circuit ≤ 85 ps
Pulse Generator Aberrations ±1% (after 1 ns)
Pulse Length 25.5 μs
Waveform Averaging 1 to 128
Operating Temperature Range -40° to +85°C
Power Supply Unregulated 12 Vdc (9.6 to 16 Vdc)
150 mA maximum, USB powered (5 Vdc)
Dimensions 21.6 x 5.1 x 10.7 cm (8.5 x 2.0 x 4.2 in.)
Weight 0.79 kg (1.75 lb)

Waveform Sampling

-NOTE- 20 to 10112 waveform values over chosen length

Distance is Vp=1. Time is one-way travel.
Range
  • 0 to 3800 m (distance)
  • 0 to 27.75 μs (time)
Resolution
  • 1.35 mm (distance)
  • < 4.4 ps (time)

Electrostatic Discharge Protection

Air ±8 kV @ 2 Ω
Contact ±4 kV @ 2 Ω
Surge ±2 kV @ 2 Ω

Current Drain

During Measurement 120 mA
Sleep Mode 1 mA